[5.1] The Status Byte
The slave replies the status register in response to command 10. The register contains information about bus collisions, resets, supply voltage, and stand-by mode.
Bit Number
Status
.7
Bus Collision bit is set
.6
Stand-by mode is selected
.5
-open-
.4
External voltage supply available
.3
-open-
.2
Remote voltage is above 15V
.1
-open-
.0
Reset flag